Turbosound Computer Drive RACKDP 50 User Manual

RACKDP-50  
QUICK REFERENCE GUIDE  
PLEASE DOWNLOAD PRESETS  
FOR THIS PRODUCT  
Turbosound Ltd  
Star Road, Partridge Green  
West Sussex RH13 8RY  
tel: +44 (0)1403 7101447 fax: +44 (0)1403 710155  
Version 1.0  
 
user guide  
RACKDP-50  
place this in your CD-ROM drive, or alternatively download the drivers from the Turbosound  
website.  
Windows XP driver installation  
Connect a USB cable from your computer to the BvNet interface or USB connector of the  
RACKDP-50. The connection brings up the ‘Found New Hardware’ Wizard.  
Insert the CD and Click ‘Next’. Once the USB BvNet Device has finished installing you will be  
prompted to install the USB BvNet Port. Click ‘Next’.  
RACKDP-50 user guide v1.0  
Page 3  
 
user guide  
RACKDP-50  
COM Port  
The TurboDrive application uses a COM port to communicate with the connected devices.  
The driver software causes a ‘Virtual COM port’ (VCP) to be created. This will appear to  
TurboDrive as just another COM port, and can be selected using Network > Com Port. To find  
out the COM port which BvNet is using, select Start > Control Panel > System > Hardware > Device  
Manager > Ports. Here you should see an entry in the tree for an item called ‘USB BvNet Port’.  
Against this will be the COM port number.  
If you wish to change this to a different COM port number, right-click on the existing COM  
port tree node; select Properties > Port Settings > Advanced. There you will see a COM port  
selector. Do not change it to a COM port that is already in use.  
Install the TurboDrive Software  
Download the TurboDrive software from the Turbosound website and follow the download  
and installation instructions. Launch the TurboDrive installer. Select a suitable installation  
directory and click ‘Next’. Then view and agree to the software license and click ‘Next’. You  
should then see the ‘Installation Complete’ screen. TurboDrive is now ready for you to use.  
Connect your Amplifier  
Connect the RACKDP amplifier(s) to your PC either via USB, or at distances greater than 3  
metres via a BvNet interface. To connect additional devices simply link the BvNet LINK  
socket on the first amplifier to the BvNet IN socket of the next device, and so on. The order  
in which the devices are connected is not important. The LINK socket of the last device in  
the ‘chain’ need not be connected. The ‘Ethercon’ connectors are fully compatible with  
standard RJ45 Ethernet patch cables which may be used to make these connections. If  
additional ruggedness is required, we recommend using the Neutrik Ethercon locking type  
of connector.  
You're now ready to run TurboDrive for the first time...  
FIRST USE OF TURBODRIVE  
Authorisation Code  
When TurboDrive is launched for the first time, or is installed into a different directory, you  
will be asked you to enter an Authorisation code: PJLUWZ. This code can also be found as a  
text file with your download.  
Enter the code and click Done.  
RACKDP-50 user guide v1.0  
Page 4  
 
user guide  
RACKDP-50  
Go Online  
Press the Go Online button  
The software then searches the network for any connected devices. During the data transfer  
process, the loading bar in the bottom-right corner of the screen will display progress.  
Once online, the triangle in the button turns green and all connected devices are displayed  
in the network window.  
Wink  
The wink button can help you test communications and find your way through a large  
network of devices. Select a device in the sidebar by clicking on its name once. Clicking the  
Wink button will cause the selected device’s ONLINE indicator to flash for a few seconds in  
order to identify itself.  
RACKDP-50 user guide v1.0  
Page 5  
 
user guide  
RACKDP-50  
IN USE  
To begin controlling a device, double click its icon in the network window. This will open a  
Monicon, a quick display showing monitor levels and mute status.  
Monicons are ideal for keeping an eye on systems with multiple devices, as the critical  
elements of a system can be viewed on a single screen. The Monicon is purely a display  
window and does not allow you to control parameters. To alter the parameters of a device,  
press the Expand button.  
tabs for each of the available control pages. To shrink the full panel back to a Monicon,  
press the Cract button.  
The control panel will now expand showing a number of  
Load Factory Settings  
To load presets into your amplifier, go to File > Load Factory Settings.. and navigate to the  
location where you have saved the downloaded .dfa preset file for your loudspeaker model.  
The selected preset name will now be displayed in the left panel and at the top of each  
device’s main window.  
RACKDP-50 user guide v1.0  
Page 6  
 
user guide  
RACKDP-50  
Grouping  
The grouping function offers a powerful way of organising multiple devices into groups,  
whose parameters can then be controlled together.  
To create a group, left-click the first device, shift-left-click the last device, right-click any of  
the selected devices and select ‘Create new Device Group’. You can name your new group  
in the left panel.  
Now, when a chosen parameter is altered, the value for all the devices in that group change  
together.  
Device Firmware  
Firmware is a set of instructions which runs inside the device, designed to inform your  
processor of its purpose and functions. As part of our programme of continuing  
improvement, firmware updates may be released from time to time, and when you launch a  
panel for a device it may recommend that you update the firmware. You can use  
TurboDrive to update the firmware in an attached device.  
Firmware files can be identified by the .dfw (device firmware) extension. The file name will  
contain the device model number (before the V) and firmware version (after the V) number  
as shown below. So, in the above example, the firmware is for Model 1169 ( -4) and its  
version number is 1.234. You should always use the same model as the one you are  
updating, and always update to a newer firmware version – never revert to an earlier  
version.  
RACKDP-50 user guide v1.0  
Page 7  
 
user guide  
RACKDP-50  
Updating Device Firmware  
To update an attached device’s firmware, go to Device > Update Firmware, then locate the  
During the firmware updating process, the progress bar in the bottom-right corner of the  
screen will turn red. DO NOT disturb the update process during this time.  
Turbosound Limited  
Star Road  
Partridge Green  
West Sussex RH13 8RY  
United Kingdom  
RACKDP-50 user guide v1.0  
Page 8  
 

Technicolor Thomson CRT Television T 7025 UD User Manual
Thermo Products Burner PGL20 180 User Manual
Toshiba Network Card MK2016GAP User Manual
TP Link Wireless Office Headset TL WA730RE User Manual
Tripp Lite Power Supply 2U Tower Stand User Manual
Ultra Products Battery Charger ULT40033 User Manual
Universal Remote Control Universal Remote SL 8000 User Manual
Vector Camping Equipment VEC1197 User Manual
ViewSonic Projection Television VX2268WM User Manual
Weber Charcoal Grill 41093 User Manual