ECs, mCs, & PCs
27”, 30”, 36” wide, single,
PLANNING
GUIDE
091605
1/2
Classic wall ovens
“C”
Alternate
Electrical
Location
Recommended
Electrical
Location
1
1“ (25mm) Min.
3
3
“A”
1“ (25mm) Min.
Clear to Top of
Door for Heat
Exhaust
“B”
2
Alternate
Electrical
Location
CUToUT DImENsIoNs
2 1/2”
(64mm)
1 1/2”
(38mm)
to finished
Countertop
Typical Counter
1
Recommended
Electrical
Location
Alternate
Electrical
Location
36”
(914mm)
typ.
“A”
“B”
2
3
3
4“ Typical Toe Kick
1“ (25mm) Min.
to Combustible Floor
CUToUT DImENsIoNs
INsTALLED UNDEr-CoUNTEr
Models
27”
“A” Cutout Height
27 3/8” (695mm)
27 3/4” (705mm)
“B” Cutout Width
“C” Min. Cabinet Width
27” (686mm)
Oven Overlays
25 1/2” (648mm)
28 1/2” (724mm)
34 1/2” (876mm)
3/4” (19mm) Each Side; 15/16” (24mm) Top;
1/16” (1mm) Bottom
30”
30” (762mm)
36”
36” (914mm)
NOTES:
1. 24” (610mm) minimum interior cabinet depth.
Back of cabinet may need to be removed.
2. 3/4” (19mm) support platform (flush with cutout).
3. 1/8” (3mm) minimum clearance to adjacent cabinet
doors/drawers.
4. Not approved in a stack configuration.
5. See the Combination Installation (CI) Section if
installing with a microwave, cooktop, or downdraft.
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
1.1
|
Cortelco Cordless Telephone 8012 User Manual
Dell Refrigerator T8144 User Manual
Dynex Portable DVD Player DX PDVD7 User Manual
Electro Voice Microphone N D967 User Manual
Euro Pro Carpet Cleaner EP965 User Manual
Everpure Water System EV9266 12 User Manual
Frigidaire Dehumidifier DH300EY5 User Manual
GE Double Oven JBP79 User Manual
Gefen Network Card TSE100 User Manual
GE Oven JKP75BMBB User Manual